3.5.0 (RSL) BCCH INFOrmation (BCINF)

-------0 Transparency bit Not transparent to BTS

0000110- Message Group Common Channel Management messages

00010001 Message Type 17

Channel Number

00000001 IE Name Channel Number

-----000 time slot number 0

10000--- channel BCCH

System Info Type

00011110 IE Name System Info Type

----0001 SYS Info Type SYSTEM INFORMATION 1

0000-і-і Spare

L3 Information

00001011 IE Name L3 Information

00000000 Spare

00010101 LLSDU Length 21

******** DTAP LLSDU 06 19 00 10 00 00 00 00 00 00 00 00

00 00 00 00 00 00 9D 00 00

DTAP 6 SYSINF 1

RR Message System Information Message

DTAP GSM 04.08 Rev 3.11. 0 (DTAP) System Information Type 1 (SYSINF1)

----0110 Protocol Discriminator radio resources management msg

-000---- Transaction ID value TI value 0

0------- Transaction ID flag message sent from orig TI

-0011001 Message Type 0x19

0--і-і-і Extension bit

Cell Channel Description

----0000 CA ARFCN 124- 121 0

-і00-і-і Spare

00------ Cell allocation Band number 0

00010000 CA ARFCN 120 – 113 16

00000000 CA ARFCN 112 – 105 0

00000000 CA ARFCN 104 – 097 0

00000000 CA ARFCN 096 – 089 0

00000000 CA ARFCN 088 – 081 0

00000000 CA ARFCN 080 – 073 0

00000000 CA ARFCN 072 – 065 0

00000000 CA ARFCN 064 – 057 0

00000000 CA ARFCN 056 – 049 0

00000000 CA ARFCN 048 – 041 0

00000000 CA ARFCN 040 – 033 0

00000000 CA ARFCN 032 – 025 0

00000000 CA ARFCN 024 – 017 0

00000000 CA ARFCN 016 – 009 0

00000000 CA ARFCN 008 – 001 0

RACH control parameters

-------1 Call Reestablishment not allowed in the cell

------0- Cell Barred for Access not barred

--0111-- TX-integer (Slots used) [10]

10------ Maximum retransmissions Max [4]

-------0 Access Control Class 8 not barred

------0- Access Control Class 9 not barred

-----0-- Emergency Call allowed to all MS’s

----0--- Access Control Class 11 not barred

---0---- Access Control Class 12 not barred

--0----- Access Control Class 13 not barred

-0------ Access Control Class 14 not barred

0------- Access Control Class 15 not barred

-------0 Access Control Class 0 not barred

------0- Access Control Class 1 not barred

-----0-- Access Control Class 2 not barred

----0--- Access Control Class 3 not barred

---0---- Access Control Class 4 not barred

--0----- Access Control Class 5 not barred

-0------ Access Control Class 6 not barred

0------- Access Control Class 7 not barred

Рис.6 Приклад BCCH SYS_INFO 1 повідомлення

GSM 08.58 Rev 3.5.0 (RSL) BCCH INFOrmation (BCINF)

-------0 Transparency bit Not transparent to BTS

0000110- Message Group Common Channel Management messages

00010001 Message Type 17

Channel Number

00000001 IE Name Channel Number

-----000 time slot number 0

10000--- channel BCCH

System Info Type

00011110 IE Name System Info Type

----0010 SYS Info Type SYSTEM INFORMATION 2

0000-і-і Spare

L3 Information

00001011 IE Name L3 Information

00000000 Spare

00010110 LLSDU Length 22

******** DTAP LLSDU 06 1A 0B 39 30 00 00 00 00 00 00 00

00 00 00 00 00 00 80 9D 00 00

DTAP 6 SYSINF 2

RR Message System Information Message

DTAP GSM 04.08 Rev 3.11. 0 (DTAP) System Information Type 2 (SYSINF2)

----0110 Protocol Discriminator radio resources management msg

-000---- Transaction ID value TI value 0

0------- Transaction ID flag message sent from orig TI

-0011010 Message Type 0x1A

0--і-і-і Extension bit

Neighbour Cells Description

----1011 BA ARFCN 124 - 121 11

---0---- BCCH alloc Seq No Ind 0

-і0--і-і Spare

00------ BCCH allocation number Band number 0

10111001 BA ARFCN 120 – 113 185

00111011 BA ARFCN 112 – 105 59

00110000 BA ARFCN 104 – 097 48

00000000 BA ARFCN 096 – 089 0

00000000 BA ARFCN 088 – 081 0

00000000 BA ARFCN 080 – 073 0

00000000 BA ARFCN 072 – 065 0

00000000 BA ARFCN 064 – 057 0

00000000 BA ARFCN 056 – 049 0

00000000 BA ARFCN 048 – 041 0

00000000 BA ARFCN 040 – 033 0

00000000 BA ARFCN 032 – 025 0

00000000 BA ARFCN 024 – 017 0

00000000 BA ARFCN 016 – 009 0

00000000 BA ARFCN 008 – 001 0

PLMN permitted

-------0 NCC 0 not permitted

------0- NCC 1 not permitted

-----0-- NCC 2 not permitted

----0--- NCC 3 not permitted

---0---- NCC 4 not permitted

--0----- NCC 5 not permitted

-0------ NCC 6 not permitted

1------- NCC 7 permitted

RACH control parameters

-------1 Call Reestablishment not allowed in the cell

------0- Cell Barred for Access not barred

--0111-- TX-integer (Slots used) [10]

10------ Maximum retransmissions Max [4]

-------0 Access Control Class 8 not barred

------0- Access Control Class 9 not barred

-----0-- Emergency Call allowed to all MS’s

----0--- Access Control Class 11 not barred

---0---- Access Control Class 12 not barred

--0----- Access Control Class 13 not barred

-0------ Access Control Class 14 not barred

0------- Access Control Class 15 not barred

-------0 Access Control Class 0 not barred

------0- Access Control Class 1 not barred

-----0-- Access Control Class 2 not barred

----0--- Access Control Class 3 not barred

---0---- Access Control Class 4 not barred

--0----- Access Control Class 5 not barred

-0------ Access Control Class 6 not barred

0------- Access Control Class 7 not barred

Рис.7 Приклад BCCH SYS_INFO 2 повідомлення

GSM 08.58 Rev 3.5.0 (RSL) BCCH INFOrmation (BCINF)

-------0 Transparency bit Not transparent to BTS

0000110- Message Group Common Channel Management messages

00010001 Message Type 17

Channel Number

00000001 IE Name Channel Number

-----000 time slot number 0

10000--- channel BCCH

System Info Type

00011110 IE Name System Info Type

----0011 SYS Info Type SYSTEM